Guide ยท Locking
The previous guide covered tab washers and nylon insert nuts. Two locking families remain: the metal version of friction locking - the all-metal prevailing-torque nut - and chemical locking - the thread locker. This guide covers how each locks, how to account for torque, how to pick a grade, and when to scrap.
About the figures: temperature limits, reuse counts, cure times and grade data are third-party published figures (fastener suppliers and engineering references), not our own measurements. Prices are not published; specifications and pricing are quoted per machine.
The previous guide covered positive locking (round nut plus tab washer) and the polymer branch of friction locking (nylon insert nuts). Two families remain: the metal branch of friction locking - all-metal prevailing-torque nuts - and chemical locking - thread lockers. Both turn up often on woodworking machinery: clamp screws, bearing lock seats, motor end-cap bolts.
The all-metal prevailing-torque nut does its locking in the thread itself: at manufacture, the upper threads are deliberately distorted - squeezed oval, dented at three points, or tapered. As the nut runs on, the bolt threads push the distorted section back toward its true form, and the metal's elastic recovery clamps the bolt. That grip acts before any clamp load exists - again a prevailing torque, same principle as the nylon insert in the last guide, except the material is the nut's own steel.
Characteristics, one by one:
With a prevailing-torque nut the tightening arithmetic changes: total torque = prevailing torque + the torque producing clamp load. Third-party sources repeat one warning: tightening to a plain-nut torque table under-clamps the joint - part of the torque is consumed by the distorted threads, so less reaches the clamp.
When fitting a new nut on a shaft swap, either add the manufacturer's published prevailing torque to the total, or switch to angle-controlled tightening. Feel is especially unreliable here: the nut resists along the whole run, and heavy resistance says nothing about how tight the joint is.
Temperature: with no polymer element, the ceiling is the steel and plating themselves - published figures run from about 300°C upward depending on material, well past the 120°C line of standard nylon. Near heat sources, drying lines or motor housings, keep nylon parts away and let the all-metal nut take the position.
Reuse: published sources put it above nylon inserts (figures from 5 to 15 cycles, varying by supplier), but the criterion is not the count - it is the residual prevailing torque, with published test standards (the ISO 2320 family) defining the floor. A nut that threads in freely has lost its lock - the same shop test as for nylon parts: resistance while threading means still alive; smooth means replace.
The price, stated plainly: metal on metal wears the bolt threads at every cycle - a nylon insert wears itself, an all-metal nut wears the screw. On repeat disassemblies, check the bolt thread quality too; on stainless pairs watch for galling, and replace both parts if a pair has seized.
Thread locker is anaerobic: it cures without air and in contact with metal ions, which is exactly the environment inside a thread gap. Cured, it fills the clearance and stops micro-movement. Three strengths plus a wicking grade, per third-party published data:
| Grade | Removability | Typical range (published) | Typical use |
|---|---|---|---|
| Low strength (purple) | hand tools | up to about M12 | adjusting screws, small parts serviced often |
| Medium strength (blue) | ordinary hand tools | about M6-M20 | general assembly, parts that need later service |
| High strength (red) | needs local heat, about 250°C, to remove | to about M25 (larger sizes have own grades) | positions not meant to be opened |
| Wicking (green) | low viscosity, applied after assembly | fasteners already tightened | field remediation |
The real cost of a wrong grade: red on a part that gets serviced means heating tools at the next maintenance, and possibly a sheared bolt; the other way round, a low grade on a heavily vibrating joint amounts to no lock at all. Clamp screws - which come off at every insert indexing - are a common case for blue; red goes on positions genuinely meant to stay closed.
| Rule | Why |
|---|---|
| Clean, dry threads before applying | oil and dust are common cure failures - a wood-shop dust environment especially |
| Activator on stainless/plated parts | passive surfaces carry few metal ions - slow cure, low strength |
| Wait before running the machine | fixture in about 10-20 minutes, full cure about 24 hours at room temperature - starting early means the adhesive has no strength |
| Sparing dose | excess adhesive squeezed out never cures and migrates into bearings and oil ways |
| Prime the bottom of blind holes | trapped air pushes the liquid back out as the bolt seats - fill from the bottom |
One more: shelf life. Anaerobic adhesives expire roughly 12-24 months after opening; expired product cures weak - do not treat it as normal stock.
| Check | Pass | Scrap / fix |
|---|---|---|
| All-metal prevailing-torque nut | consistent drag over the whole run | threads in freely (prevailing torque lost) |
| Torque setting | prevailing torque + clamp torque, summed | plain-nut torque table used as-is |
| Partner bolt thread | smooth engagement, full thread form | shiny wear, visible slop |
| Locker grade | blue or red chosen by "will this be opened again?" | red used on frequently serviced parts |
| Cure time | full cure before load | machine started right after assembly |
Read the three guides together: positive locking (washers) handles "lock it solid", friction locking (nylon / all-metal nuts) handles "keep it from turning", chemical locking (adhesive) handles "keep it from moving". Each has its own pass/fail tests - mix the tests and you find nothing. Adhesive is always a second layer on top of a working mechanical lock, not a substitute.
More durable than a nylon insert, but not indefinitely: published reuse figures run 5-15 cycles depending on supplier. Judge by residual prevailing torque, not the count - hand-thread before reuse; consistent drag allows cautious reuse, a free-running nut is scrap.
No. Total torque = prevailing torque + clamp-load torque, and the distorted threads consume part of it - a plain table under-clamps. Add the manufacturer's published prevailing torque, or use angle-controlled tightening.
Not recommended. Clamp screws come off at every insert indexing; red needs local heat of about 250 C to release, so the next service needs heating tools and risks a sheared bolt. Blue medium strength is the common choice there: ordinary tools remove it, vibration resistance is adequate.
Fixture time about 10-20 minutes, full cure about 24 hours at room temperature. Starting early puts vibration onto adhesive with no strength - effectively no lock. For same-day restarts, prefer a mechanical locking part over adhesive.
Yes, advisedly. Stainless, plated and anodised surfaces are passive - few metal ions, slow cure, reduced strength. Third-party guidance lists the missing activator among the common causes of adhesive failure on stainless.
Specifications and pricing are per machine; prices are quoted after dimensions are confirmed. Third-party figures are cited as published and are not our own measurements.